热门站点| 世界资料网 | 专利资料网 | 世界资料网论坛
收藏本站| 设为首页| 首页

SAE J2382 Video Based Light Measurement Techniques

作者:标准资料网 时间:2024-05-14 05:48:00  浏览:9901   来源:标准资料网
下载地址: 点击此处下载
Product Code:SAE J2382
Title:Video Based Light Measurement Techniques
Issuing Committee:Test Methods And Equipment Stds Committee
Scope:Traditional methods of photometry rely on the use of a goniometer to rotate the test item around two axes at right angles. This method is satisfactory for most situations but has certain disadvantages:a. Point-by-point measurements with a goniometer may be slow. With more advanced requirements, particularly for headlamps, where the entire beam pattern is of concern, isocandela measurements are becoming increasingly needed. Such testing can be very time consuming.b. For production quality assurance, the speed of a goniometer may not allow testing to keep pace with the production line if a large quantity of lamps must be sampled.c. High Intensity Discharge (HID) lamps are becoming commonly used. Such lamps are orientation sensitive, changing in both lumen output and intensity distribution when tilted. This can introduce significant inaccuracies in test results when testing is performed using a goniometer.There is a need for alternative test techniques which can achieve very high speed data acquisition, the capture of full isocandela distribution, and the elimination of lamp tilting. This SAE Informational Report describes fundamentals of video-based testing to address these concerns. Further information is required to provide all details needed to set up a laboratory using these techniques.With the video-based system, the lamp is fixed in position and aimed at a receiving screen. A camera, of particular type and grade, views the screen and is able to perform measurement of the reflected light (luminance) at each point on the screen. Proper calibration of the system can provide the luminous intensity distribution of the light under test from the measured luminance values.Numerous factors must be taken into account to produce an accurate measurement system. Under controlled conditions, it has been shown that the system can produce measurement of absolute intensity distributions with good accuracy. (Reference 2.1.1 and 2.1.2.)The great advantage of this form of photometry is its extremely high speed, allowing the collection of isocandela diagrams in less than one minute. There are some accompanying disadvantages which are discussed later.This document describes the basic techniques and the controls which are necessary for accuracy.Comments are also provided comparing video based technology to conventional goniometer methods.
下载地址: 点击此处下载
基本信息
标准名称:机械密封用碳化硼密封环 技术条件
中标分类: 机械 >> 通用零部件 >> 密封与密封装置
替代情况:被JB/T 6615-2011代替
发布部门:合肥通用机械研究所
发布日期:1993-05-07
实施日期:1994-01-01
首发日期:1900-01-01
作废日期:2011-08-01
归口单位:合肥通用机械研究所
出版日期:1900-01-01
页数:5 页
批文号:机械科[1993]127号
适用范围

本标准规定了机械密封用碳化硼密封环的技术要求、试验方法、检验规则和包装、运输、贮存等内容。 本标准适用于热压碳化硼密封环。工作条件为压力不大于6.3MPa,温度在-20~+200℃的水、油类、有机溶剂、强酸强碱及带有固体颗粒的介质。

前言

没有内容

目录

没有内容

引用标准

没有内容

所属分类: 机械 通用零部件 密封与密封装置
【英文标准名称】:Medicalelectricalequipment--Particularrequirementsforthesafetyofultrasonicphysiotherapyequipment
【原文标准名称】:医用电气设备.超声治疗设备安全专用要求
【标准号】:JIST0601-2-5-2005
【标准状态】:现行
【国别】:日本
【发布日期】:2005-03-25
【实施或试行日期】:
【发布单位】:日本工业标准调查会(JP-JISC)
【起草单位】:TechnicalCommitteeonMedicalEquipment
【标准类型】:()
【标准水平】:()
【中文主题词】:
【英文主题词】:
【摘要】:この規格は,2.1.101で定義する,医用超音波物理療法機器の安全に関する要求事項について規定する。
【中国标准分类号】:C41
【国际标准分类号】:11_040_60
【页数】:16P;A4
【正文语种】:日语



版权声明:所有资料均为作者提供或网友推荐收集整理而来,仅供爱好者学习和研究使用,版权归原作者所有。
如本站内容有侵犯您的合法权益,请和我们取得联系,我们将立即改正或删除。
京ICP备14017250号-1